For CT1501 heating/cooling

Connect the wires to matching terminals on
the subbase.

A

POWER SOPPLV, PROVIDE DISCONNECT MEANS AND

■ OVERLOAD PROTECTION AS REQUinED.

NOTE: If there are four wires, connect wire

marked R to terminal RH arid add a jumper
wire to connect to RC. If RC is left uncon­
nected, the air conditioner will not turn on. The

4-wire drawing on this page shows how to jumper

RC to RH Strip the insulation off the wire

where it connects to the terminals. Firmly tighten
screws.

4-WIRE SYSTEM

A POWER SUPPLY. PROVIDE DISCONNECT MEANS AND

OVERLOAD PROTECTION AS REQUIRED.

A\

INSTALL JUMPER BETWEEN RC AND RH.

If the labels do not agree with the terminal

designations on your new subbase:

• Refer to Table 2 on page 8,

• Determine correct hookup from the listed

control function and the equipment control
circuit.