5. Insert the element into the element opening and

slip the asbestos washer over the capillary (Fig. 4).
With the 2 screws provided, securely fasten the control
to the furnace casing.

6. Position the element as described in Location

above, bending as necessary. Avoid sharp bends or
repeated flexing with the self-supporting model (Fig. 2).

FLEXIBLE CAPILLARY MODEL

The element must be firmly held in position by use

of capillary support. Part No. 107324A, or similar
support (Fig. 5).

WIRING

REPLACEMENT OF SIMILAR DEVICE BY THE

L4017

Adapter plate bag assembly. Part No. 21136E, is

available to fit mounting holes of similar controls

(Fig. 6).

CAUTION

Disconnect power supply before connecting wiring
to prevent electrical shock or equipment damage.

All wiring must comply with applicable local codes

and ordinances. Follow the system wiring diagrams
furnished with the burner. Figs. 7 and 8 illustrate the
connections to the L4017. For ease in wiring, 2 conduit
knockouts are furnished at the bottom, and 1 at the top
of the case.

CAUTION

A jumper is provided between the fan and the
limit terminals. This jumper is used when both the
fan and the limit switches are switching line voltage
circuits. When the high limit switch is used in the
low voltage circuit, remove this jumper.

FIG. 7-CONNECTIONS TO L4017 WITH LIMIT

SWITCH IN LINE VOLTAGE CIRCUIT (JUM­

PER IN PLACE).

NORMALLY
OPEN-CLOSES
ON TEMP.
RISE OR

MANUALLY
ON L401 78

NORMALLY

CLOSED-
OPENS
ON TEMP. RISE

(LOW VOLTAGE)
IN SERIES
WITH PRIMARY^
CONTROL *4
CIRCUIT

ADD

DISCONNECT

MEANS AND

OVERLOAD

PROTECTION

AS

REQUIRED.

2600B

FIG. 6-ADAPTER PLATE AND DIMENSIONS, IN

INCHES [MILLIMETERS IN BRACKETS].

FIG. 8-CONNECTIONS TO THE L4017 WITH LIMIT

SWITCH IN LOW VOLTAGE CIRCUIT (JUM­
PER REMOVED).