Product data sheets – Kenmore Coldspot 106 User Manual

Page 24

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

PRODUCT DATA SHEETS

Base Grille Water Filtration System Model WF-NLC250/NLC250

Tested and certified by NSF Internationa! against ANSI/NSF Standard

42 for the reduction of Chlorine (Class I) Taste and Odor and against

ANSI/NSF Standard 53 for the reduction of Lead, Cysts and Turbidity.

Capacity;

250 Gallons (946 Liters)

Service Flow Rate:

0.5 GPM (1

.89

L/min.)

@

60 psi.

Substance Reduction

U.S. ERA

Average

Maximum

Average

Minimum %

Average %

NSF Test

Aesthetic Effects

MCL

Influent

Effluent

Effluent

Reduction

Reduction

Number

Chlorine Taste/Odor

N/A

1.9 mg/L

N/A

0.04 mg/L

N/A

97.9%

994707

Particulate

N/A

610,000/mL*

N/A

154/mL

N/A

99.97%

994711

Contaminant

U.S. ERA

Average

Maximum

Average

Minimum %

Average %

NSF Test

Reduction

MCL

Influent

Effluent

Effluent

Reduction

Reduction

Number

Cyst

99.95%“

89,250/mL*

6/mL

2.3/mL

99.993%

99.997%

994710

Turbidity

0.5 NTU

29 NTU

0.1 NTU

0.09 NTU

99.5%

99.69%

994710

Lead: @ pH 6.5

0.015 mg/L

0.16 mg/L“*

0.001 mg/L

0.001 mg/L

99.4%

99.4%

994708

Lead:

@

pH 8.5

0.015 mg/L

0.16 mg/L*“

0.002 mg/L

0.001 mg/L

98.8%

99.4%

994709

Base Grille Water Filtration System Model WF-LC400/LC400

Tested and certified by NSF International against ANSI/NSF Standard

42 for the reduction of Chlorine (Class I) Taste and Odor and against

ANSI/NSF Standard 53 for the reduction of Lead, Cysts and Turbidity.

Capacity: 400

Gallons

(1514

Liters)

Service Flow Rate: 0.5

GPM

(1.89 L/min.) <

( 60 psi.

Substance Reduction

U.S. ERA

Average

Maximum

Average

Minimum %

Average %

NSF Test

Aesthetic Effects

MCL

Influent

Effluent

Effluent

Reduction

Reduction

Number

Chlorine Taste/Odor

N/A

2.0 mg/L

N/A

0.04 mg/L

N/A

98%

994707

Particulate

N/A

610,000/mL*

N/A

154/mL

N/A

99%

994711

Contaminant

U.S. ERA

Average

Maximum

Average

Minimum %

Average %

NSF Test

Reduction

MCL

Influent

Effluent

Effluent

Reduction

Reduction

Number

Cyst

99.95%“

89,250/mL*

6/mL

2.3/mL

99.993%

99.997%

994710

Turbidity

0.5 NTU

29 NTU

0.12 NTU

0.09 NTU

99.59%

99.69%

994710

Lead: @ pH 6.5

0.015 mg/L

0.16 mg/L*“

0.001 mg/L

0.001 mg/L

99.4%

99.4%

994708

Lead:

@

pH 8.5

0.015 mg/L

0.16 mg/L*“

0.002 mg/L

0.001 mg/L

98.8%

99.4%

994709

■ Refer to the “Warranty” section for the Manufacturer’s limited

warranty.

Application Guidelines/Water Supply Parameters

Water Supply

City or Well

Water Pressure

30- 120 psi (207 - 827 kPa)

Water Temperature

OS'* -100°F (O.e” - ST.S” C)

It is essential that operational, maintenance, and filter
replacement requirements be carried out for the product to
perform as advertised.

■ Model WF-NLC250

Change cartridge at least every 6-9

months. Use replacement cartridge NLC 250, part# 9902.
2000 suggested retail price of $39.95 U.S.A./S49.95 Canada.

■ Model WF-LC400

The filter monitor system measures the

amount of water that passes through the filter and alerts you

to replace the filter. When 90% of the filter’s rated life is used,
the filter indicator light changes from green to yellow. When

100% of the filter’s rated life is used, the filter indicator light
changes from yellow to red, and it is recommended that you
replace the filter. Use replacement cartridge LC400, part#
9902. 2000 suggested retail price of $39.95 U.S.A./$49.95
Canada.

The product is for cold water use only.

Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after

the system.

Refer to the “Assistance or Service” section for the
Manufacturer’s name, address and telephone number.

‘Test requirement is at least 100,000 particles/ml of AC Fine Test Dust. “Cyst performance is

%

reduction based on NSF Standard 53. ‘“Test

requirement is 0.15 mg/L ± 10%. These contaminants are not necessarily in your water supply. Performance may vary based on local water conditions.

® NSF is a registered trademark of NSF International.

24

Advertising