BYPASS VALVES

Bypass valve(s) should always remain In soft water
service position. Position in “bypass” only if needed for
softener repairs.

SINGLE BYPASS

Inches

cm

A

Salt Tank Height

34

86.4

B

Resin Tank Diameter
(nominal)

10

25.4

C

Resin Tank Height (nominal)

40

101.6

D

Inlet-Outlet Height

41-1/2

105.4

E

Overall Height

48

121.9

Fi

Length

21

53.3

F2

Width

17

43.2

-

Distance between inlet-outlet
centerlines

3-3/4

8.6

Bypass

valve

Inlet

valve

FIG. 59

MODEL NO. 625.384260 - TIMER CODE H46

WATER SUPPOr TO WATER SOFTENER

Minimum water system flow (gpm)

3

Minimum-maximum water pressure (psi)

20 - 125

Minimum-maximum water temperature (°F)

40 - 120

Maximum water hardness (gpg)

160

Maximum “clear water” iron (ppm)*

11

SALT FOR WATER SOFTENER

Type of salt needed

nugget

Alternate type of salt

pure, evaporated, compacted

water softener salt

gpm = gallons per minute gpg = grains per gallon

psi = pounds per square inch ppm = parts per million

' Capacity to remove clear water iron is substantiated by WQA test data. State of Wisconsin requires

additional treatment if water supply contains greater than 5 ppm clear water iron.

Questions? Call The Kenmore Water Line 1-800-426-9345