DESCRIPTION OF OPERATION

This appliance is one of the most advanced water

heaters available. It provides a continuous supply of
hot water at a preset temperature. This appliance is
direct vent where air is brought in from the outside and
combustion gases are exhausted to the outside.

While electricity, water, and gas supplies are connected,
this appliance produces hot water whenever a hot water
tap is open.

Ignition is electronic. There is no pilot light consuming

gas while the water heater is not being used. The gas

burner lights automatically when the hot water tap is

opened and goes out when the tap is closed. Installation
of the temperature controller is highly recommended.
The temperature controller can set the temperature
within a specific range and can provide error codes to
diagnose any problems.

The temperature of the outgoing hot water is constantly

monitored. This appliance may adjust the water flow
in order to maintain the temperature setting. The

water flow may vary from summer to winter due to the

difference in ground water temperature.

OPERATING INSTRUCTIONS

Sequence of Operation

1. Water Flow Begins

Water Flow Sensor sends a pulse to the electronic
control board

Electronic control board senses flow greater than

0.6 GPM

Firing Sequence begins

2. Firing Sequence

Electronic control board monitors inlet/outlet water

temperature, temperature set point, and water
flow rate.

Combustion fan energized. Purges combustion

chamber.

Spark igniter begins sparking.

Gas control valve opens to minimum fire rate.

Flame rod proves ignition

Spark igniter stops sparking

3. Normal Operation

Electronic control board monitors flame rod,

fan motor frequency, outlet water temperature,

controller temperature set point and water flow
rate.

Gas control valve modulates gas input to required

firing rate.

Combustion fan speed is adjusted for the required

firing rate.

Water flow control valve is adjusted as needed.

4. Shutdown Sequence

Electronic control board senses water flow rate

less than 0.5 GPM.

Gas control valve closes.

Water flow control valve resets to standby

position.

Combustion fan runs for a short period of time at

low speed.

5. Standby Mode

Electronic control board monitors water temperature

and remote controls

Freeze protection is activated as needed.

Features Available on Temperature Controllers

The temperature controller is supplied with the
appliance. Dimensions (inches): 3.5 W x 4.75 H x 0.75 D.

In Use

Indicator

Temperature

Display

Thermostat

n

u

o

Priority

—Hot water temp.

On/Off

Priority

Indicator

Priority

Button

ON/OFF

Button

Features

Description

Error Codes

When a fault is detected an error code
flashes at the temperature

In Use Indicator

Indicates that hot water is being supplied
(i.e. a hot water tap is open).

ON/OFF Button

Used to turn the water heater ON or OFF.

Priority Button /
Indicator

Indicates that this controller is setting the

temperature . Priority can be switched to
another controller by pressing its Priority

Button when no hot water is running.

Temperature Display Shows the temperature setting.

Thermostat

Increases or decreases the temperature

setting.

Figure 13

24

305 & 505 Indoor Manual