Flushing the Heat Exchanger (Error Code: LC or 00)

An “LC” or “00” error code indicates the unit is beginning
to lime up and must be flushed. Failure to flush the

appliance will cause damage to the heat exchanger.
Damage caused by lime build-up is not covered by the
unit’s warranty. After flushing, reset the LC fault code by
turning off the power to the unit and turning the power
back on.

1

.

2

.

3.

4.

5.

6

.

7.

8

.

9.

Disconnect electrical power to the water heater.

Close the shutoff valves on both the hot water and
cold water lines (V3 and V4).

Connect pump outlet hose (H1) to the cold water
line at service valve V2.

Connect drain hose (H3) to service valve V1.

Pour approximately 4 gallons of virgin, food grade,

white vinegar or citric acid into pail.

Place the drain hose (H3) and the hose (H2) to the
pump inlet into the cleaning solution.

Open both service valves (V1 and V2) on the hot

water and cold water lines.

Operate the pump and allow the cleaning solution
to circulate through the water heater for at least 45
minutes.

Turn off the pump.

a. Rinse the cleaning solution from the water

heater as follows: a. Remove the free end of the
drain hose (H3) from the pail.

b. Close service valve, (V2), and open shutoff

valve, (V4). Do not open shutoff valve, (V3).

c.

d.

Allow water to flow through the water heater for

5 minutes.

Close service valve, (V1), and open shutoff
valve, (V3).

10. Disconnect all hoses.

11. Remove the in-line filter at the cold water inlet and

clean out any residue. Place filter back into unit.

13. Restore electrical power to the water heater.

3/4" Ball Valve

s

Pressure Regulator

3/4" Union

Circulating Pump

Check Valve

Boiler Drain Valve

Pressure Relief Valve

eia

Solenoid Valve

Figure 15