GASKET

607709

■GASKET 807710

locating

pin

CLAMPING RING

807712

PUMP HOUSING

807711

FIGURE 40

RBpIscing Pump und Motor Assembly (Msnufsciur&d in 1978 or Lutar)

1. Replace 807710 gasket

DO NOT

try to re-use origina! gasket. Be sure ridges on gasket face downward

2

5

6

.

Place pump and motor assembly in mounting hole in tub bottom. Be sure ports on pump housing are adjacent

to connecting ends of drain and recirculating hoses

Join together the two halves of the clamping ring on the pump housing Make sure the locating pins in the clamping

ring halves are inserted in the holes in the pump housing. The joined ring wil! stay in position on the pump housing
when R is properly assembled.

Install the pump mounting screws.

IMPORTANT: Install one screw on each side of the ring FIRST

See Figure

41

Attach hoses to pump housing ports. Secure damps with clamp screw on underside of hose

Connect motor leads disconnected in Step #4 in "Removing Pump and Motor Assembly.

7, Replace lower spray arm, lower rack, toe plate, and access panel

NSTAIL THESE SCREWS FIRST

JOINT-

FIGURE 41

4 1