Figure 48 – Kenmore 808353 User Manual

Page 49

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

FIGURE 48

Connecting a voltmeter in series with the Bi-IVletal as shown in Figure 48 will permit a quick cheek of the circuit
If the circuit is good, line voltage will be indicated when the timer is advanced to the Detergent Dispenser Inctcmenl
with thè dishwasher connected to a pov^er source. The Bi-Meta! will not heal with the voltmeter connected, due lo

the high resistance of the meter.

Failure of the Bi-Metal to operate can usually be traced to a poor connection, faulty contact or an open lead The
Bi-Metal itself is a highly reliable component, If the circuitry is found to be satisfactory, the latching surfaces of
the cam and trigger should be checked for roughness.

CAUTION^ Do not apply line voltage across the Bi Metal, as this would destroy it

The Bi-Metal leaf is an integral part of the electric circuit. If it becomes necessary to touch the leaf for any leason,
turn off the power to the dishwasher. Although the Bi-Metal is a low voltage component, it is possible to have a
120 volt potential from the Bi-Metal to ground when the Bi-Meta! circuit is open

Ref.

No

Description

1,

Bi-Metal Trigger

2

Screw

3.

Screw

4.

Cam

5.

Roll Pin-Cam

6

.

Spring-Cam

7

Sprtng-Cam-Compression

8

Nut

9

Bracket-Actuator

10,

Washer

11

Bushing

12,

“0” Ring

13

Shaft

14.

Cup-Detergent

15.

Cover-Cup

16

“0" Ring

4 6

Advertising