Failure of the Bi-IVleia! to lift can usually be traced to an interruption of its circuit
element The rinse injector Bi-Melal is very similar to that for the detergent cup, and d is checked m the same manner.
A voltmeter may be used in series with the Bi-Metal (see Figure 53) to check for an open circuit condition. Reference
should be made to the proper schematic wiring diagram to locate such a condition

CAUT/ON:

Do not apply line voltage across the Bi-Metal as this would destroy it. A voltmeter
across the Bi-Metal terminal will indicate approximately one volt if operation is correct

but a poor connection at the Bi-Metai terminal could show line voltage.

Leaking Welling Agent Dispenser - Bi-Metal Type

Overfilling the welling agent dispenser can cause the liquid to be forced past P'f "^er when
This liquid will run down the door between the door and outer panel and may dnp to the floor, Make sure that the

door of the dishwasher does not open past the horizontal position This may cause the wetting agent to leak out.
This can be corrected by raising the front levelers slightly on undercounter models