SUPER TRADEUNE

Y594G (T874G/Q674F)

THERMOSTAT/SUBBASE PACKAGE OR

T874R THERMOSTAT/

Q674L SUBBASE

INSTALLATION INSTRUCTIONS FOR THE TRAINED SERVICE TECHNICIAN

APPLICATION

These thermostats and subbases provide 24 to 30 Vac control for two-stage heating and one-stage cooling heat pump

systems as follows:

MODEL

CHANGEOVER

. SYSTEM SWITCHING

FAN SWITCHiNG

Y594G (T874G/Q674F)

Automatic (Heat or Coo!)

OFF-EM.HT.-HEAT-

AUTO-COOL

AUTO-ON

T874R/Q674L

Manual

EM.HT.-HEAT-OFF-COOL

AUTO-ON

On a two-heat thermostat, the two stages Of heat

“make” sequentially as the temperature drops. “Make”

refers to the mercury switch initiating a call for heat or
cool.

There Is about 2 F [1.1 C] between stages so that the

second stage (auxiliary heat) makes only when the first
stage can’t handle the load. This is the interstage

differential.

Three LEDs (light-emitting diodes) are included on the

OPERATION

subbase. The red CHECK LED lights when something

needs to be checked or done to maintain efficient

operation of the system. See your heating system

instructions to find out specifically what the CHECK LED
signifies. The green LED lights when the AUX. HT. stage
(second stage) heat Is operating. The red EM.HT. LED
lights when the EM.HT. relay is energized, usually

operating electric strip heaters.

WHEN INSTALLING THIS PRODUCT . . .

1. Read these instructions carefully. Failure to follow

them could damage the product or cause a hazardous

condition.

2. Check the ratings given in the instructions and on

the product to make sure the product is suitable for your
application.

3. Installer must be a trained, experienced service

technician.

4. After installation is complete, check out product

operation as provided in these Instructions.

INSTALLATION

MOUNTING THE SUBBASE

The thermostat subbase can be mounted on a vertical

outlet box, horizontal outlet box, or directly on the wall.

1.

If you must mount the subbase on a vertical outlet

box, order 193121A Adapter Assembly (Fig. 1). The

assembly includes an adapter ring, two screws, and a

cover plate to cover marks on the wall. Install the ring and
cover plate on the vertical outlet box.

CAUTION

1. Disconnect power supply to prevent electrical

shock or equipment damage.

2. Run wires as close to the subbase as possible.

To prevent interference with the thermostat

linkage, keep wire length to a minimum. Push

excess wire back into the hole, and plug hole to

prevent

drafts

from

affecting

thermostat

operation.

3. Do not overtighten thermostat captive mounting

screws as damage to subbase threads may
result.

4. Do not short across coil terminals on relay. This

may burn out the heat anticipator.

LOCATION

Install thethermostat about 5 ft [1.5 m] above the floor in

an area with good circulation at average temperature.

Do not install the thermostat where it may be

affected by—

—drafts, or dead spots behind doors and in

corners.

—hot or cold air from ducts.

—radiant heat from sun or appliances,
—concealed pipes and chimneys.
—unheated (uncooled) areas behind the ther­

mostat, such as an outside wall.

A

ACCESSORY PARTS AVAILABLE 1.193121 A).

Fig. 1—Installation of subbase on outlet box.

S.M.

Rev. 5-86e

Form Number 69-0272~>1