4. system switch functions, 5. 8251ac controls, Mz3s00 – Sharp MZ-3500 User Manual

Page 65: Start

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

6-3. Block diagram of the interface

MZ3S00

Peripheral

6-4. System switch functions

ON

OFF

SW5

Causes an error when the

ER signal is low or open

during data output.

ER signal is disabled.

SW6

Always high when power is

on to the main unit.

The CD signal is set high
while data output, but

would not be set high

when the echo-back
furKtion is selected for

the host computer.

SW7

Causes on error when the
PO signal is high during

data output.

Polarity is inverted.

6-5. 8251AC controls

There are two control words for the 8251 AC.

(1) Mode instruction: Defining general operational para­

meters, such as unit, stop bit, etc.

(2) Command instruction: Defining status words used for

actual operation, such as send/receive enable, etc.

1) Definition of generation operational parameters

• Baud rate

• Character size

• Even/odd/off parity assignment

-•Stop bit size

'Corresponds to channel command of BASIC.

c

START

J

8251AC internal reset

8251AC mode instruction

72 -