Cable locks – Cisco 600W User Manual

Page 13

Advertising
background image

13

Step 3

Connect the DC-input end of the cable to a Cisco RPS rear-panel connector as shown in Figure 14 or Figure 15.

Figure 14

Connecting a One-to-One Cable to a Cisco RPS for Quasi-Redundant Power

Figure 15

Connecting a Two-to-One Y-Cable to a Cisco RPS for Fully Redundant Power

Step 4

On the Cisco RPS rear panel, connect one or two AC power cables. A single AC power cable can go into either AC
connector. Two AC power cables provide parallel AC power sources. Use the cable locks on the Cisco RPS to lock the
cables in place. (See Figure 16.)

Figure 16

Connecting AC Power Cables to the Cisco RPS

88108

AC INPUT 1

100-200 V~ 50/60 Hz

10-5 A 1000 W

AC INPUT 2

100-200 V~ 50/60 Hz

10-5 A 1000 W

DC OUTPUT 1

DC OUTPUT 2

DC OUTPUT 3

DC OUTPUT 4

88107

AC INPUT 1

100-200 V~ 50/60 Hz

10-5 A 1000 W

AC INPUT 2

100-200 V~ 50/60 Hz

10-5 A 1000 W

DC OUTPUT 1

DC OUTPUT 2

DC OUTPUT 3

DC OUTPUT 4

29092

Cable locks