T—figure 6. the – Cisco 600W User Manual

Page 9

Advertising
background image

9

Fully redundant—Figure 7. The power source is fully redundant because there are two AC input modules and two DC
output power modules connected to each external device. If any power module fails, there is a full backup.

Note

This configuration is not supported for switches and hubs.

Redundant with reboot—Figure 8. In normal operation, the hub or switch is powered directly by its AC power connection.
If the internal power system of the hub or switch fails, the device powers down for about 30 seconds until the Cisco RPS
begins supplying power.

Note

Redundancy with reboot works for the following devices only: FastHub 400 series hubs, Catalyst 1900 series and
Catalyst 2820 switches, and Catalyst 2900 series and Catalyst 3500 series XL switches.

Mixed quasi-redundant and fully redundant—Figure 9. Three external devices can be powered, with two in
quasi-redundant mode and one in fully redundant mode.

Figure 6

Quasi-Redundant Configuration

Figure 7

Fully Redundant Configuration

External devices

150W or less

DC output

AC input

DC

DC

AC

AC

DC

DC

Cisco RPS

NM3998

DC output

AC input

DC

DC

DC

DC

Cisco RPS

11962

AC

AC