Channel Vision C-0315 User Manual

Description, Instructions, Specifications

Advertising
background image

C-0315 15dB RF Amplifier

234 F

ISCHER

A

VENUE

z C

OSTA

M

ESA

, CA 92626

(714) 424-6500 z (800) 840-0288 z (714) 424-6510

FAX

http://www.channelvision.com z e-mail: [email protected]

Description

Channel Vision’s 15dB power injected inline amplifier provides the lowest induced noise figure available and is
designed with the future in mind. Unlike other RF amplifiers, the C-0315 features a bi-directional return path for

12VDC IN RF INPUT

Channel Vision

MULTI-ROOM AUDIO VIDEO TECHNOLOGY

CVT-15PIA

5-42MHz RETURN PATH PASS
54-1000MHz FORWARD PATH

3dB LOW NOISE AMPLIFIER

15dB GAIN

OUT-PWR

Cable or
Antenna

12VDC IN RF INPUT

Channel Vision

MULTI-ROOM AUDIO VIDEO TECHNOLOGY

CVT-15PIA

5-42MHz RETURN PATH PASS

54-1000MHz FORWARD PATH

3dB LOW NOISE AMPLIFIER

15dB GAIN

OUT-PWR

Cable or
Antenna

HS-3

CVT-PI

880

DC Blocker

Standard Wiring Layout

Layout with Power Injector

C-0315

C-0315

Instructions

Step 1: Mount amplifier.
Step 2: Connect cable or antenna signal to the INPUT jack.
Step 3: Connect OUTPUT jack to distribute signal to all the TV’s in the house.
Step 4: Connect power to 12VDC input, or use PIA (power injector) for remote power capability. Note: must use

DC passive splitters.




Please Note:
The unused trunk line connector of the last outlet device in each trunk line MUST BE TERMINATED using a
75

Ω terminator (model 2101).

Specifications

Parameter Condition Min Typ Max
Gain
f=54MHz 13.5 14.5 15.5
f=1000MHz 14.0 15.5 17.0
Flatness 54-1000MHz - +/-0.8 -
Insertion Loss 5-40MHz -1.5 - -0.5
Return Loss IN 5-40MHz - -18 -14
54-750MHz - -20 -16
750-1000MHz - -16 -14
Return loss OUT 5-40MHz - -18 -14
54-750MHz - -20 -16
750-1000MHz - -16 -14
Tap - Tap Isolation 54-1000MHz - - -
2nd Order Input Intercept - 80 - -
3rd order input intercept
- 60 - -
Composite Second Order - - - -60
Composite Triple Beat - - -70 -60
Noise Figure 54-60MHz - 3 3.5
60-750MHz - 2.4 3.0
750-1000MHz - 3 4.0
Hum Modulation - - - -70
Return Path Level 5-27MHz - - 60
27-40MHz - - 40
RFI Isolation 5-1000MHz - - -130

Warning

To prevent fire or shock hazard, do not expose this appliance to rain or moisture

Advertising