Wattage (W)

Model with

controls white

Model with controls

silver

Model with no

controls white

Dimensions

(mm)

500

NPP50 75-773001

NPP50S 75-773011

NP50 75-772901

442 x 430 x 80

1000

NPP100 75-773002

NPP100S 75-773012

NP100 75-772902

680 x 430 x 80

1500

NPP150 75-773003

NPP150S 75-773013

NP150 75-772903

680 x 430 x 80

2000

NPP200 75-773004

NPP200S 75-773014

NP200 75-772904

852 x 430 x 80

Creda Newera Profile and Profile Plus Panel Heaters

Installation and Operating Instructions














The Newera Profile panel heater range is designed for wall mounting on the wall brackets supplied. It
should only be operated when in the upright position as shown in diagram C.
All models are protected against moisture ingress to IPX4 standard.
All models, except those with no controls, are fitted with a 7-day digital programmer.
Installation:
Before connecting the heater, check that the supply voltage is the same as that stated on the rating label.
When selecting the position for the heater to be installed, consideration should be given to ensure that there
are no obstructions closer than the dimensions given in Diagram C. The bracket for the heater should be
fitted in accordance with the method detailed in the associated diagrams. The heater must not be located
below a socket outlet or connection box.
Care must be exercised when fitting the heater onto the bracket. Pressure should only be applied to
the ends of the heater and not to the grille area.
The electrical installation must be carried out by a competent electrician and in accordance with the current
Electrical Wiring Regulations (BS7671) and/or local regulations.
The heater is fitted with a length of flexible cable for connection to the fixed wiring of the premises via a
suitable connection box positioned adjacent to the heater.
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly
qualified persons in order to avoid a hazard.
A means for disconnection in all poles must be incorporated in the fixed wiring in accordance with
the wiring rules.

WARNING – THIS APPLIANCE MUST BE EARTHED