Haltech E6X Manual DOS Version User Manual

Warnings

Advertising
background image

E6X Manual

i




Warnings


1. This system is capable of controlling either “intelligent” igniters

which have in-built dwell control or “dumb” igniters which rely
on the ECU to control dwell. This allows standard igniters to be
used in many cases. Most standard igniters are dumb igniters.
However, it is very important to set the system up to match the
type of igniter used. In the ignition set-up page the set-up should
be:

To control intelligent igniters set up as “Constant Duty
To control dumb igniters set up as “Constant Charge

If the wrong set-up is used the system will not function correctly
and it is possible that the igniters may burn out as a result.
Burning out of igniters due to incorrect set-up will not be
regarded as warranty.

2. The E6X ECU must only be used with an E6X wiring

harness. The E6K ECU must only be used with an E6K wiring
harness. Note that the wiring harness of the E6K will physically
plug into the E6X ECU (and vice-versa), however, the pin
connections are different and this will lead to improper operation
of the ECU and possible damage to it. The E6X wiring harness
is clearly labelled as “E6X” near the main ECU connector.


Advertising