Cisco ONS 15454 SDH User Manual

Page 31

Advertising
background image

15-31

Cisco ONS 15454 SDH Reference Manual, R4.6

April 2008

Chapter 15 Performance Monitoring

15.6.3 STM-4 and STM4 SH 1310-4 Card Performance Monitoring Parameters

15.6.3 STM-4 and STM4 SH 1310-4 Card Performance Monitoring Parameters

Figure 15-10

shows the signal types that support near-end and far-end PM parameters for the STM-4 and

STM4 SH 1310-4 cards.

Figure 15-11 on page 15-31

shows where overhead bytes detected on the ASICs

produce performance monitoring parameters for the STM-4 cards and the STM4 SH 1310-4 card.

Figure 15-10 Monitored Signal Types for the STM-4 and STM4 SH 1310-4 Cards

Note

PM parameters on the protect VC4 are not supported for MS-SPRing.

Figure 15-11 PM Read Points on the STM-4 and STM4 SH 1310-4 Cards

The PM parameters for the STM-4 and STM4 SH 1310-4 cards are described in

Table 15-34 on

page 15-32

through

Table 15-38 on page 15-34

.

71106

ONS 15454

SDH

E1

STM-N

Fiber

Near End

STM-N Signal

High-Order VC-4 and VC-4Xc Path PMs Supported for the Near-End

ONS 15454
SDH

E1

STM-N

Far End

STM-N Signal

ONS 15454 SDH

STM-4 and STM4-4 Cards

BTC ASIC

XC Card

E1

RS-EB
RS-BBE
RS-ES
RS-SES

MS-EB
MS-BBE
MS-ES
MS-SES
MS-UAS

HP-PPJC-Pdet
HP-NPJC-Pdet
HP-PPJC-Pgen
HP-NPJC-Pgen

HP-EB
HP-BBE
HP-ES
HP-SES
HP-UAS
HP-ESR
HP-SESR
HP-BBER

PMs read on BTC ASIC

Note: The STM-4 has 1 port per card and the STM4-4 has 4 ports per card.

71109

Advertising