Description

This kit will replace pressure switch
assembly shown in Figure 1 with
pressure switch assembly shown in
Figure 2. Use this instruction guide for
assembly and operation information.
This guide is designed to supplement
the other instruction manuals included
with this unit. Carefully read all
manuals and safety information before
operating the compressor.

Components

Pressure switch - Auto/Off Switch - In
the "auto" position, the compressor
shuts off automatically when tank
pressure reaches the maximum preset
pressure. In the "off" position, the
compressor will not operate. This switch
should be in the "off" position when
connecting or disconnecting the power
cord from the electrical outlet or when
changing air tools.

Regulator - The regulator controls the
amount of air pressure released at the
hose outlet.

ASME Safety Valve - This valve
automatically releases air if the tank
pressure exceeds the preset maximum.

Removal of Existing Switch

1. Disconnect power and release all air

pressure from tank.

2. Remove existing pressure switch

cover screw(s), then remove cover.

3. Locate cut-outs on the back of

pressure switch (See Fig. 3). Insert
tip of small screwdriver into cutouts,
then push to release wires.

IN606401AV 10/04

BUILT TO LAST

O

O

TT

UU

AA

F

F

F

F

O

O

4. Remove ground screw (Fig. 3).

5. Remove strain relief screw (Fig. 3).

6. Pull unloader tube off existing

pressure switch. Remove screw
holding pressure switch to pressure
switch assembly. Then remove
switch from unit.

7. Disconnect unloader tube from

check valve.

8. Remove the remainder of pressure

switch assembly by unscrewing tank
fitting.

New Switch Installation

New switch must
have same max-

imum pressure as existing switch.
Pressure rating is listed on the bottom
of assembly.

1. Screw pressure switch assembly onto

tank.

2. Replace existing unloader tube

connection at check valve with new
quick connect supplied in kit.

3. Insert new unloader tube into quick

connect fitting on check valve.

4. Insert other end of unloader tube

into unloader valve on pressure
switch. Unloader tube can be cut if
supplied length is too long.

5. Loosen pressure switch cover screw,

then remove cover.

6. Two strain relief clamps will be

provided in the kit. Determine which
strain relief clamp to use based on
the diameter of the line cord.

7. Loosely attach strain relief clamp to

pressure switch with screw provided

!

CAUTION

Figure 2

OUTLET PRESSURE

REGULATOR

TANK PRESSURE

DRAIN
MOISTURE FROM TANK
WEEKLY TO PREVENT
TANK CORROSION

AUTO

OFF

Figure 1

Cutouts

Strain Relief Screw

Ground Screw

Figure 3

For parts, product & service information

visit www.chpower.com

© 2004 Campbell Hausfeld/Scott Fetzer

REMINDER: Keep your dated proof of purchase for warranty purposes! Attach it to this manual or file it for safekeeping.

2

11

3

4

5

6

7

8

9

10

1

Notes
Notas

Additional Operating Instructions
Instructions d’Utilisation Additionnelles
Instrucciones Adicionales

CW301300AJ, CW301400AJ

Advertising
This manual is related to the following products: