UB-502D and UB-752D

Forced-Air Heaters

WARNING: Hazard of Electric Shock. Disconnect all
power before installing heater.

Note: These heaters are designed for wall or ceiling mounting
only. Other modes of mounting voids factory warranty.
1. Height above floor

A. In areas where ceiling height is more than 12 feet, recom-

mended mounting height is approximately 10 feet to under-
side of heater.

B. For ceiling heights of 12 feet or less, maximum mounting

height is determined by use of ceiling mounting brackets
offered for these heaters. Minimum spacing to ceiling is 3”
(see Figure 2).

C. In either case, minimum mounting height is 7 feet from

floor to bottom of heater. (See Figures 1 and 2.)

2. Spacing to adjacent walls

A. Rear of case to back wall 4-7/8” minimum (see Figure 2).
B. Side of case to side wall 6” minimum (see Figure 2).

3. If two or more units are operated in the same enclosed space,

their discharges should be directed to aid in development of
mass air movement for uniform heat dispersal.

4. Controlling thermostats to individual heaters should be

mounted at shoulder height on inside walls or columns.

‡ Model Numbers with suffix “T” added (480 volts only) are equipped with a transformer, 480V Primary — 120/240V Secondary.
‡ Model Numbers with suffix “R” added are equipped with a relay.

Horizontal

Model

Voltage and Phase

kW

Air Discharge

(Ft.)

UB-502D

120 (1ø); 208, 240 or 480 (1ø or 3ø)

5

12.5

UB-502D-R

208, 240 or 480 (1ø or 3ø)

5

12.5

UB-752D

120 (1ø); 208, 240 or 480 (1ø or 3ø)

7.5

13

UB-752D-R

208, 240 (3ш); 480 (1ш or 3ø)

7.5

13

Specifications —

Dimensions —

Rubber Feet Provided for

Wall Mount Units Only.

7/8” and 1-13/32”
Dia. Holes in Rear

11-5/8”

13-5/8”

17-3/16”

8-7/8”

7-9/16”

For Lower Height
from Ceiling:
Customer to add
Extension Strap.

11-7/8”

8”

6”

7’-0” Min. Height

Above Floor

Figure 1

Mounting UB using ceiling

mounting brackets*

Ceiling Line

Wall

Back

Wall

6” Min. Spacing to

Adjacent Wall

3”

4-7/8”

8-7/8”

15-9/16”

7’-0” Min. Height

Above Floor

Mounting

Holes

Center

8”

6”

Figure 2

Mounting UB using wall

mounting brackets*

*Wall and/or Ceiling Mounting Brackets are
available as an accessory option — Contact
local sales representative.