26

Summary of the Others menu modes and settings

Number, mode and

Content

default display

01 Checking the firmware version

Displays the firmware version of the mechanical control and im-
printer.

Mx.xx:

Mechanical control firmware version.

Fx.xx:

Imprinter firmware version. This entry is blank if the optional
imprinter for DR-4080U is not installed.

02 Setting the buzzer

Switches the scanner buzzer alert off and on.

0 2 . B u z z e r

O N

ON OFF

When the buzzer is on:

1 buzz: Short buzz every time a key is pressed.

1 buzz: Long buzz after every scanning job completes normally.

5 buzzes: Error

03 Setting the SCSI ID

Sets the SCSI ID number for the scanner.

0 3 . S C S I

I D

N o . 0

No.0 No.1 No.2 No.3 No.4 No.5 No.6 No.7

After you select a number for the SCSI ID number, press Home then
switch the scanner off and switch it on again.

04 Setting the terminator

Activates and deactivates the terminator.

0 4 . T e r m i n a t o r

D i s a b l e

Disable Enable

Disable:

Select if another SCSI device is connected to the scanner,
i.e. a SCSI interface cable connects the scanner to the next
device in the SCSI chain.

Enable:

Select if the scanner is the last device in the SCSI chain.

In order for this setting to take effect, you must switch the scanner off
and switch it on again.

05 Checking the Clean Roller

Tells you when it is time to clean the rollers. When this display
nears 100% clean the rollers.

100%: Rollers must be cleaned. (

38)

0%:

Displayed after setting is cleared (see 05 below).

05 Clearing the Clean Roller

Press together to clear the Clean Roller Warning. After the
warning is cleared and reset to 0%, “Completed” is displayed in
the LCD.

06 Checking the roller modules

Tells you when it is time to replace the roller modules. When this
display nears 100% replace the modules.

100%: Rollers must be cleaned. (

38)

0%:

Displayed after setting is cleared (see 06 below).

06 Clearing the roller modules

Press together to clear the roller module replacement warn-
ing. After the warning is cleared and reset to 0%, “Completed” is
displayed in the LCD.

Setting up the scanner

0 1 . V e r s i o n

0 5 . C l e a n

W a r n i n g

R o l

l e r

0 %

replacement warning

0 6 . R e p l a

W a r n i n g

c e

R o l

l .

0 %

0 6 . R e p l a c e

R o l

l .

C l e a r = < >

Warning

0 5 . C l e a n

W a r n i n g

R o l

l e r

C l e a r = < >

replacement warning

Warning status

Advertising