Maintenance – Craftsman 919.15216 User Manual

Page 14

Advertising
background image

14 - ENG

MAiNTeNANCe

Customer Responsibilities

Before

each use

Daily

or after

each

use

see tank

warning

label

Check Safety Valve

x

Drain Tank

x

Remove tank from service

x(1)

1

- For more information, Contact a Trained Service Technician.

Unit cycles

automatically when

power is on. When performing

maintenance, you may be exposed

to voltage sources, compressed air,

or moving parts. Personal injuries

can occur. Before performing any

maintenance or repair, disconnect

power source from the compressor

and bleed off all air pressure.
NOTE:
See Operation section for the

location of controls.

To Check Safety Valve

Risk of Bursting.

If the safety valve

does not work properly, over-

pressurization may occur, causing

air tank rupture or an explosion.

Risk from Flying

Objects. Always

wear certified safety equipment:

ANSI Z87.1 eye protection (CAN/CSA

Z94.3) with side shields
Before starting compressor, pull the ring

on the safety valve to make sure that the

safety valve operates freely. If the valve

is stuck or does not operate

smoothly,

it must be replaced with the same type

of valve.

To Drain Tank

Risk of Unsafe

Operation. Risk

from noise. Air tanks contain high

pressure air. Keep face and other

body parts away from outlet of

drain. Use ANSI Z87.1 eye protection

(CAN/CSA Z94.3) when draining as

debris can be kicked up into face.

Risk from noise.

Use ear protection

[(ANSI S12.6 (S3.19)] hearing

protection) as air flow noise is loud

when draining.
1. Set the On/Off switch to "Off".
2. Turn the regulator knob counter-

clockwise to set the outlet

pressure to zero.

3. Remove the air tool or accessory.
4. Pull ring on safety valve allowing

air to bleed from the tank until

tank pressure is approximately

20 psi. Release safety valve ring.

5. Drain water from air tank by

opening drain valve on bottom of

tank.

Risk of Bursting.

Water will condense

in the air tank. If not drained, water

will corrode and weaken the air tank

causing a risk of air tank rupture.

Risk of Property

Damage. Drain water

from air tank may contain oil and

rust which can cause stains.
6. After the water has been drained,

close the drain valve. The air

compressor can now be stored.

NOTE: If drain valve is plugged,

release all air pressure. The valve

can then be removed, cleaned, the

reinstalled.