Alarm Port Connection

Figure 14

Connecting the Alarm Port Cable

Connect the dry relay alarm port cable connector to the alarm port. It cannot be inserted incorrectly.

The dry relay alarm port operates up to 50V AC/DC maximum and up to 80 mA maximum. Total power dissipation should not
exceed 300 milliwatts. The normally closed position will have from 15 to 30 ohms resistance. The open position will be greater
than 1 megohm. The alarm condition is the closed position. This port is a switch so that the cable connector can be inserted in
either orientation.

Cable Management

Figure 15

Inserting the Cables Through the Cable-Management Bracket

If you have not already done so, run the port adapter and input/output cables through the cable-management bracket.