3 port protection, 4 isolation relays, Nxt 2-d/4-d controller – Keri Systems NXT 4-D User Manual

Page 3: Installation guide

Advertising
background image

NXT 2-D/4-D Controller

Installation Guide

Page 3 of 6

P/N: 01997-001 Rev. I

1.3

Port Protection

Transorbs are provided with the controller ship kit. They are used to protect the controller from voltage spikes induced on
the port wiring by absorbing the excess voltage and slowly releasing it back into the circuit. Keri strongly recommends
wiring in the transorbs provided with the controller ship kit. Refer to the Transorb Wiring Diagram below.

NOTE: The Transorbs that Keri provides are non-polar; they can be installed in either orientation.

1.4

Isolation Relays

For locking devices that may induce heavy voltage spikes – Mag Locks and devices with heavy-duty solenoids such as
turnstiles, vehicle gates, and overhead doors – Keri recommends using isolation relays. Keri has an Isolation Relay Kit

(p/n IRP-1). Please refer to the IRP-1 Isolation Relay Installation Guide (p/n 01833-001) for detailed information.

1

2

3

4

5

6

NO - Relay

Common - Lock / Alarm - Relay

NC - Relay

Door Switch - Input

Ground

REX - Input


+

Power

Supply

Fail-Secure

Electric Lock Device

or

Alarm

+

1

2

3

4

5

6

NO - Relay

Common - Lock - Relay

NC - Relay

Door Switch - Input

Ground

REX - Input

+ Power

Supply

Fail-Safe

Electric Lock

Device

+

Port

Terminal Block

Port

Terminal Block

Advertising