Keri Systems SB-293 Quick Start User Manual

Sb-293 satellite board, Sb-293 quick start guide, 0 specifications

Advertising
background image

SB-293 Satellite Board

1530 Old Oakland Road, Suite 100

01837-003 Rev. 2.3

San Jose, CA 95112 USA
(800) 260-5265 (408) 451-2520 FAX (408) 441-0309
Web: http://www.kerisys.com E-mail: [email protected]

Page 1 of 16

SB-293

Quick Start Guide

This quick start guide is made up of a specification sheet, basic installation drawings and information, and short
descriptions of key terms and concepts. For comprehensive information regarding the SB-293 Satellite Board, please
refer to the Technical Reference Manual (P/N 01836-004).

1.0

Specifications

Unit Dimensions

PXL-250 controller PCB with an SB-293 Satellite Board
-

7.25 inches high by 6.00 inches wide by 1.75 inches deep, including wiring connectors

-

(18.45 cm by 15.25 cm by 4.45 cm)

PXL-250 controller PCB with an SB-293 Satellite Board and an LCD-1 Alpha/Numeric Display
-

8.10 inches high by 6.00 inches wide by 1.75 inches deep, including wiring connectors

-

(20.60 cm by 15.25 cm by 4.45 cm)

Enclosure
-

9.70 inches high by 8.20 inches wide by 2.60 inches deep

-

(24.65 cm by 20.85 cm by 6.60 cm)

Operating Temperature/Humidity Range

0°F to 140°F (-18°C to 60°C)

0% to 90% Relative Humidity, non-condensing

Controller with Satellite Board Power Requirements

12 VDC @ 1 Amp

Current Draw

maximum current draw 270 mA for a controller plus reader current draw (refer to Table 1 for Reader current draw)

120 mA max for a PXL-250 Controller

150 mA max for an SB-293 Satellite Board

Output Relay Contact Rating

1 Amp @ 24 VDC

Input Device Configuration

Door Sense

normally closed

Request to Exit

normally open

Global Unlock

normally open, or

Auxiliary RTE A-Door

normally open

Table 1: Reader Current Draw

Reader Type

MS-3000

MS-4000

MS-5000

MS-7000

MS-9000

Current Draw

50 mA

50 mA

100 mA

200 mA

200 mA

Advertising