Appendix D

CGI Commands

32

Wireless-N Internet Home Monitoring Camera

Appendix D

Admin-Level CGI Commands (Administrator level privilege)

Query FW Version

Method:

GET

URL:

http://<ip>/adm/sysinfo.cgi

Return:

The Camera returns a Web page that contains the following messages:

HTTP/1.0 200 OK \r\n

content-type: text/plain\r\n

\r\n

Firmware Version: v1.0.00 build 01 \r\n

Serial Number: SQJ00G100001\r\n

Reboot

Method:

GET

URL:

http://<ip>/adm/reboot.cgi

Return:

HTTP/1.0 200 OK \r\n

content-type: text/plain\r\n

\r\n

OK\r\n

Restore to Factory Defaults

Method:

GET

URL:

http://<ip>/adm/reset_to_default.cgi

Return:

HTTP/1.0 200 OK \r\n

content-type: text/plain\r\n

\r\n

OK\r\n

Get/Set Group Parameters

Get group parameters

Method:

GET

URL:

http://<ip>/adm/get_group.cgi?<parameter>=<value>[&<value>…]