Oberon 1790 User Manual

Installation instructions, Poe ils

Advertising
background image

Installation Instructions

PoE ILS

(877) 867-2312www.oberonwireless.com

Rev. 02/12/13 P/N 1790

Oberon, Inc. •••• 1315 South Allen Street •••• State College, PA 16801

Copyright 2013



Assembly Components:
- PoE ILS assembly – 1 each
- #8-32 X 3/8 “ screw – 4 each
- Installation instructions – 1 each




If any of these items are missing, contact your Oberon representative.


Find a flat work surface to assemble the ceiling enclosure, PoE ILS, access point and antenna(s) prior to mounting in ceiling.


Step 1 - The PoE ILS is designed to be used with Oberon enclosures. At the time of this writing, the only enclosure that
accommodates the PoE ILS is the Oberon Model 1052-00.


Step 2 – Install the PoE ILS board into the 1052-00
with the four supplied screws. Mount the PoE ILS such
that the switch is facing outward toward the door, as
shown in Figure 1.








Step 3

Route the incoming Ethernet cable through

the 1052-00 following the instructions provided with
the enclosure, and insert the RJ-45 connector into the
IN port on the PoE ILS. The port locations are shown
in Figure 2.





Step 4 Route the incoming Ethernet cable through
the 1052-00 following the instructions provided with
the enclosure, and insert the RJ-45 connector into the
IN port on the PoE ILS. The port locations are shown
in Figure 2.









Page 2



Step 4 – If desired, during WAP testing or maintenance, to provide power to the WAP with the enclosure door open a PC
jumper (customer provided) can be used on the two pin jumper located beside the switch on the PoE ILS board.

Ensure

that the jumper is not left in place during normal operation, or the PoE ILS will be bypassed.















































Page 3

Figure 1 - Hardware installation.

Figure 2

Optional Bypass

Jumper Pins

Input Port

Output Port

To WAP