Multiple baseboard wiring - optional, Baseboard wiring with a wall thermostat - optional – Cadet 8F2000 User Manual

Page 5

Advertising
background image

B

A

MULTIPLE BASEBOARD WIRING. 240V SUPPLY ONLY
(See Figure 14)
1. Left side wiring: disconnect factory connector A. Right

side wiring: disconnect factory connector B.

2. Connect one wire from each heater to one supply wire.
3. Connect remaining wire from each heater to the

remaining supply wire.

4. Connect supply ground wire to both ground leads.

Note: Field wiring is not provided

Multiple Baseboard Wiring - Optional

Follow the instructions below if you are wiring more than one heater in parallel on same circuit.

If you are wiring multiple baseboards to one control, it is recommended that you use one control per room.

B

Do not disconnect

Ground

Field Wiring

Heater Wires

To Wall Thermostat

A

Baseboard Heater

Right Side

Baseboard Heater

Left Side

LOW

Baseboard wiring with a wall thermostat - Optional

SINGLE POLE WALL THERMOSTAT
1. Route supply wires to the thermostat wiring box (if not

already present).

2. Connect one supply wire to one thermostat wire (typically

marked L1).

3. Route remaining thermostat wire (typically marked T1)

to the baseboard heater.

4. Route remaining supply and ground wire to the baseboard

heater.

5. Follow installation instructions for mounting and wiring

baseboard heater.

DOUBLE POLE WALL THERMOSTAT
1. Route supply wires to the thermostat wiring box (if not

already present).

2. Connect one supply wire to one thermostat wire (typically

marked L1).

3. Connect remaining supply wire to other thermostat wire

(typically marked L2).

4. Route remaining thermostat wires (typically marked T1

and T2) to the baseboard heater.

5. Route ground wire to the baseboard heater.
6. Follow installation instructions for mounting and wiring

baseboard heater.

Refer to the wiring diagram below that corresponds to your thermostat application. Note: Wiring diagrams are for reference only.
See wall thermostat instructions included with your thermostat for your specific application.

For instructions on wiring using an in-built thermostat, see Cadet BTF1, BTF2 and SBFT2 Installation Instructions

Figure 12

Figure 13

Figure 14

STANDARD

BASEBOARDS

SHOWN

OFF

To Supply

Thermostat

wiring box

Thermostat

wiring box

Single Pole
Thermostat

Double Pole
Thermostat

L1

T1

L2

T2

L1

T1

To Heater

To Supply

To Heater

Advertising
This manual is related to the following products: