Country Flame Corn & Pellet User Manual

Ea b

Advertising
background image

Little Rascal

Harvester

Crossfi re

A. Stove body height

22.75"

22.75"

19.50"/ 22.75"

B. Height on legs

31.25"

31.25"

N/A

C. Width at rear

26"

25.50"

24"

D. Widest point

26"

30.75"

29"

E. Stove depth

19.75"

24.50"

24.20"

F. Insert extension on hearth

N/A

N/A

10"

G. Extension into fi replace

N/A

N/A

14.20"

Stove Clearances

Little Rascal

Harvester

J. Side to combustible

1"

2"

K. Back to combustible

1"

2"

L. Corner to combustible

1"

2"

NOTE:

Combustible fl ooring within 6" (P) of the front and within

8" (Q) of each side of the ash removal door must be covered with
non-combustible material per manufacturer’s specifi cations. The
fl oor protection on the sides of the stove only has to extend to the
vertical side wall(s) if the clearance is less than 8 inches.

Alcove:

Side and back clearances are the same as stove

clearances. Minimum alcove height 7ft. Maximum alcove depth 4ft.

Features

Little Rascal

Harvester

Crossfi re Pellet

Crossfi re Corn

Fuel type

Pellet

Corn and/or Pellet

Pellet

Corn and/or Pellet

Up to BTU/hr

40,500

50,000 Corn

40,500

54,000 Corn

Hopper capacity

45 lbs.

75 lbs.

55 lbs.

75 lbs.

Igniter

Yes

No

Yes

No

Firepot agitator

No

Yes

Yes

Yes

Heating capacity

1,200-2,000 sq. ft.

Up to 2,500 sq. ft.

Up to 2,000 sq. ft.

Up to 2,500 sq. ft.

Combustion effi ciency

99%

97%

99%

97%

Weight

275 lbs.

404 lbs.

230 lbs.

230 lbs.

Venting size - direct exhaust

3"

3"

4"

4"

Heavy duty heat exchanger

14 tube

15 tube

14 tube

14 tube

Room air blower

160 cfm

160 cfm

160 cfm*

160 cfm

Intelli-Choice™ control board

Standard

Standard

Standard

Standard

Heat level settings

5

5

5

5

Thermostat ready

Yes

Yes

Yes

Yes

Mobile home approved

Yes

Yes

Yes

Yes

Clean glass air wash equipped

Yes

Yes

Yes

Yes

Zero-clearance box approved

N/A

N/A

Yes

Yes

*Blower on the Crossfi re Pellet insert is controlled by a manual rheostat.
Special Notes: Crossfi re must be installed on non-combustible surface (see installation manual).

Insert Clearances

Crossfi re*

M. Side to combustible

7"

N. Mantel (combustible) to top of unit

9.25"

O. Hearth extension in front of door**

6"

* Must be installed on non-combustible surface
(see installation manual).
** See owner’s manual for fi replace size requirements.

Crossfi re Shroud Dimensions

Standard

Oversized

H. Height

29.50"

32.50"

I. Width

42"

48"

Mantel / Fascia / Top Trim

V1001A

Side W

all

E

A

B

Stove

H

I

Crossfi re Insert

A

A

Crossfi re Insert

F

G

front

rear

Shroud

C

D

Top View

150 Michigan St. S.E., Hutchinson, MN 55350

Phone: (800) 495-3196 Fax: (320) 587-8872

[email protected]

www.countryfl ame.com

Advertising