Casio FX-9750GII User Manual

Page 311

Advertising
background image

13-8

- Clipboard and history data (Including the “SYSTEM” data item.)

- e • ACT mode data*

1

- S • SHT mode data*

1

*

1

Can be transferred from an fx-9860G

II

SD, fx-9860G

II

, fx-9860G AU PLUS, fx-9860G SD

(OS 2.0), fx-9860G (OS 2.0) or fx-9860G AU (OS 2.0) calculator.

• Program data is transferred as-is.
However, any command in a transferred program that is not supported by the fx-7400G

II

will be replaced by the at sign (@). Running such a program on the fx-7400G

II

will cause an

error.

u Sending Data from an OS 2.0 Calculator to any Older Model Calculator

The following are general rules that apply when transferring data from an OS 2.0 calculator to
an fx-9860G series or CFX-9850G series calculator.

• The following data is not transferred.

- String memory data

- TVM mode bond calculation and depreciation calculation data

- STAT mode function and variable data for which there is no corresponding function for

variable on the receiving calculator model (Example:

Ƶ

2

GOF Test calculation result data,

etc.)

• The following data is converted by the OS 2.0 calculator to a format that is supported by the

receiving calculator model before it is sent.

- GRAPH mode, DYNA mode Graph Type setting data
When transferring to an fx-9860G series or CFX-9850G series calculator, X=, X>, X<, X

t,

and X

s type expressions are converted to an X=c type expression

- Graph line type setting data
When sending to a CFX-9850G series calculator, line settings are converted as follows

before being sent: Normal: Blue; Thick: Orange; Broken, Dotted: Green.

- STAT mode Graph1, Graph2, and Graph3 setting data
When sending to an fx-9860G series calculator, pie and bar type graphs are converted to

ScatterPlot before being sent. Other settings are not sent.

• Program data is transferred as-is.
However, any command in a transferred program that is not supported by the other model

calculator will be replaced by the at sign (@). Running such a program on the other model
calculator will cause an error.

• Refer to the following if an error message appears on the OS 2.0 calculator when you are

sending data to another calculator model.

Invalid Data Size

- Matrix data exceeds 256 rows or 256 columns*

1

- List data exceeds 256 lines

- Table data exceeds 256 rows

- Recursion table data exceeds 256 lines*

1

*

3

- EQUA mode input data includes 4 to 6-degree equation

Advertising