Storage – Craftsman 919.16644 User Manual

Page 18

Advertising
background image

18- ENG

A08597

STORAGE

Before you store the air compressor,
make sure you do the following:
1. Review the "Maintenance"

section on the preceding
pages and perform scheduled
maintenance as necessary.

2. Set the On/Auto/Off lever to

"OFF" and unplug unit.

3. Turn the regulator

counterclockwise and set the
outlet pressure to zero.

4. Remove the air tool or

accessory.

5. Pull ring on safety valve allowing

air to bleed from the tank until
tank pressure is approximately
20 psi. Release safety valve ring.

6. Drain water from air tank by

opening drain valve on bottom of
tank.

Risk of Bursting.
Water will

condense in the air tank. If not
drained, water will corrode and
weaken the air tank causing a risk
of air tank rupture and possible
serious personal injury.
7. After the water has been

drained, close the drain or drain
valve.

NOTE: If drain valve is plugged,
release all air pressure. The valve
can then be removed, cleaned, and
reinstalled.
8. Protect the electrical cord and

air hose from damage (such as
being stepped on or run over).
Wind them loosely around
the compressor handle. (If so
equipped)

9. Store the air compressor in a

clean and dry location.

Advertising