Install the battery backup, Install the lights, Installation step 7 – Chamberlain WD962KLD User Manual

Page 18: Installation step 8

Advertising
background image

18

ALWAYS wear protective gloves and eye protection
when changing the battery or working around the
battery compartment.

INSTALLATION STEP 7

Install the Battery Backup

• Make sure motor unit is unplugged.

• Using a Phillips head screwdriver, remove the battery

cover on the motor unit.

• Partially insert battery into motor unit with terminals

facing out.

• Connect the red (+) and black (-) wires from motor unit

to corresponding terminals on battery.

• Verify the battery wires are seated in the channel.

• Replace battery cover.

INSTALLATION STEP 8

Install the Lights

• Press the release tabs on both sides of lens. Gently

rotate lens back and downward until the lens hinge is in
the fully open position. Do not remove the lens.

• Install a 100 watt maximum light bulb in each socket.

Light bulb size should be A19, standard neck only.
The lights will turn ON and remain lit for approximately
4-1/2 minutes when power is connected. Then the
lights will turn OFF.

• Reverse the procedure to close the lens.

• Use A19, standard neck garage door opener bulbs for

replacement.

NOTE: Use only standard light bulbs. The use of short neck
or speciality light bulbs may overheat the endpanel or light
socket.

To prevent possible OVERHEATING of the endpanel or
light socket:

• DO NOT use short neck or specialty light bulbs.

• DO NOT use halogen bulbs. Use ONLY

incandescent.

To prevent damage to the opener:

• DO NOT use bulbs larger than 100W.

• ONLY use A19 size bulbs.

Channel

Battery
Cover

100 Watt (Max)
Standard Light Bulb

100 Watt (Max)
Standard Light Bulb

Lens
Hinge

Release Tab

Battery

Advertising