Attach the emergency release ropeand handle, Electrical requirements, Installation step 9 – Chamberlain WD962KLD User Manual

Page 19: Installation step 10, Attach the emergency release rope and handle

Advertising
background image

19

To prevent possible SERIOUS INJURY or DEATH from a
falling garage door:
• If possible, use emergency release handle to

disengage trolley ONLY when garage door is
CLOSED. Weak or broken springs or unbalanced
door could result in an open door falling rapidly and/
or unexpectedly.

• NEVER use emergency release handle unless garage

doorway is clear of persons and obstructions.

• NEVER use handle to pull door open or closed. If

rope knot becomes untied, you could fall.

INSTALLATION STEP 9

Attach the Emergency Release Rope
and Handle

• Thread one end of the rope through the hole in the top

of the red handle so “NOTICE” reads right side up as
shown. Secure with an overhand knot at least
1" (2.5 cm) from the end of the rope to prevent
slipping.

• Thread the other end of the rope through the hole in the

release arm of the outer trolley.

• Adjust rope length so the handle is 6 feet (1.8 m) above

the fl oor. Ensure that the rope and handle clear the tops
of all vehicles to avoid entanglement. Secure with an
overhand knot.

NOTE: If it is necessary to cut the rope, heat seal the cut
end with a match or lighter to prevent unraveling.

INSTALLATION STEP 10

Electrical Requirements

To avoid installation diffi culties, do not run the opener
at this time.

To reduce the risk of electric shock, your garage door
opener has a grounding type plug with a third grounding
pin. This plug will only fi t into a grounding type outlet.
If the plug doesn’t fi t into the outlet you have, contact a
qualifi ed electrician to install the proper outlet.

If permanent wiring is required by your local code, refer
to the following procedure.

To make a permanent connection through the 7/8" (2 cm)
hole in the top of the motor unit:

• Remove the motor unit cover screws and set the cover

aside.

• Remove the attached 3-prong cord.

• Connect the black (line) wire to the screw on the brass

terminal; the white (neutral) wire to the screw on
the silver terminal; and the ground wire to the green
ground screw. The opener must be grounded.

• Reinstall the cover.

To avoid installation diffi culties, do not run the opener
at this time.

To prevent possible SERIOUS INJURY or DEATH from
electrocution or fi re:
• Disconnect ALL electric and battery power BEFORE

performing ANY service or maintenance.

• Garage door installation and wiring MUST be in

compliance with ALL local electrical and building
codes.

• NEVER use an extension cord, 2-wire adapter, or

change plug in ANY way to make it fi t outlet. Be
sure the opener is grounded.

Trolley
Release Arm

Overhand
Knot

Emergency
Release Handle

PERMANENT WIRING
CONNECTION

RIGHT

WRONG

Green
Ground
Screw

Ground Tab

Ground Wire

White Wire

White Wire

Black
Wire

Black
Wire

Trolley

Advertising