For a complete explanation of these parameters, refer to page 22.

5. ENERGY key (active on E models only) which allows selection and display

of the following energy settings and permits adjustment of the energy

parameters a. through c. below in 1 joule increments (from 0 to 999,999

joules):

a. Energy Setting

b. Energy Limit Low

c. Energy Limit High

For a complete explanation of these parameters, refer to page 23.

6. AMPLITUDE key which controls adjustment of the amplitude setting,

relating to the system’s high-frequency vibrations over the full operating

range. Refer to page 23 for more information.

7. FN KEY. Option not available on this model.

8. TEST key which can be used to test the actual power output (watts).

When this key is pressed, the ultrasonics are activated and will remain on

(cycle) for 5 seconds. The number of watts will be displayed on the LCD

screen and a line will display along the bar graph on the bottom of the

LCD screen which will reflect the percentage of power output.

9. O.L. RESET key which resets the power supply following an overload

condition. Red LED in upper left corner indicates an overload condition

exists. Refer to page 24 for complete information.

10. 0-9 NUMERIC KEYPAD which allows input of numeric data by

pressing the keys.

11. CLEAR key which clears the preceding entry when pressed.

12. ENTER/REVIEW key which serves to enter data into the system and/or

to display data (or parameters) on the LCD screen.

KEYING IN PARAMETERS

To make numeric entries into a cursor location that is displayed on a screen

menu, use the numeric keypad. When the desired entry is displayed on the

LCD screen, use the ENTER key to register the new value. Entries are made

left to right.

The CLEAR key will clear an existing value to 0, displayed as a series of

dashes, and relocate the cursor to the extreme left-hand entry position ready

to accept entries again. As soon as a desired value is keyed in and displayed,

pressing the ENTER key makes the system accept that entry. If a number

value is not “Entered,” then it will not be accepted by the system and the

parameter value will return to its former setting (before any numerical values