I N S T R U C T I O N M A N U A L • H A N D H E L D W E L D E R S

Frequency Display

The TEST key can also be used to display the running ultrasonic frequency.

Refer to page 23 for more information.

READY SCREENS

In addition to the start-up ready screen (shown on page 20), there are 2 other

“ready” screens. The power supply must be displaying one of the 3 ready

screens in order for welding to commence. Welding cannot be initiated from

any other display. All 3 ready screens can be accessed by pressing the

ENTER/REVIEW key. The other 2 ready screens are as follows:

Alarm Screen

The Alarm screen displays information about the alarm(s) that have been

triggered by the system encountering parameters outside of the specified

tolerance limits. The screen will indicate whether alarms occurred in Time or

Energy (on E models only). If there are no alarms, dashes will display. If there

are alarms, an L (for Low limit, indicating that the low limit was violated)

and/or an H (for High limit, indicating that the high limit was violated) will

display by the applicable mode (time or energy). Once another new cycle is

begun, the system will automatically clear the current alarm.

Counter Screen

The Counter screen displays information about the job number, the number

of cycles run to date, the customer resettable counter (CRC) and the

resettable alarm counter (RAC). The 2 resettable counters can be reset

whenever desired by pressing the Clear key when the counter screen is

displayed (the keypad must be unlocked).

*Alarms*

Time: – –
Energy: – –

Cycles:

00,004,678

CRC: 000,062

RAC: 0,000