Operation, Actuation, Emergency stop – Sonics 2055 -Press User Manual

Page 19: Actuation emergency stop

Advertising
background image

• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •

I N S T R U C T I O N M A N U A L • M O D E L 2 0 5 0 / 2 0 5 5

18

O P E R A T I O N

ACTUATION

Each 2050 and 2055 press is equipped with two maintained anti-repeat (non-

tie-down) palm buttons, one located on the left and one on the right side of

the base of the press. Both palm buttons must be pressed simultaneously to

activate the press to cycle the welder. To operate the press, follow these

simple steps:

1. Depress both black palm buttons simultaneously.

2. Once the horn comes in contact with the part, the pressure switch closes

and the ultrasonics are activated, release the palm buttons. If you release

the buttons before contact is made, the head will immediately return to its

“home” position.

EMERGENCY STOP

To abort the 2050 or 2055 press during welding, simply press the red

EMERGENCY STOP button located at the front center of the press base.

Once the EMERGENCY STOP button has been depressed, the head will

retract and return to its “home” position. Simply rotate the EMERGENCY

STOP button clockwise 1/4 turn to release the press for further operation.

NOTE: Power supply

cannot be shut off once the

weld cycle has started.

Termination of cycle can

only be achieved by using

the EMERGENCY STOP

button.

The equipment has safety

devices that require both

hands to be on the palm

buttons until the horn

contacts the workpiece. Do

not defeat or modify

these safety devices.

Do not use with a

footswitch unless alternate

means of pinch-point

protection is provided.