I N S T R U C T I O N M A N U A L • M O D E L 2 0 5 0 / 2 0 5 5

24

PRESSURE SWITCH ADJUSTMENT

For systems mounted in the normal vertical position with downward travel, no

adjustment should be necessary. The minimum trigger pressure is factory set

at 4-7 psig.

However, if the minimum trigger pressure requires recalibration or re-

adjustment, the pressure switch can be accessed and adjusted.

To access the pressure switch, it is first necessary to remove both the side

panel cover and the pinch point cover as described above (for either the

model 2050 or 2055 press). Then, observe the following procedure:

1. Loosen the jam nut holding the 1/4-20 cap screw in place.

2. Rotate the small, knurled, threaded rod upward until the Pressure Switch

closes.

PRESSURE
SWITCH

Do not operate press

without covers in place.

PAN HEAD
SCREWS

NOTE: Pressure switch is

factory set and should not

be adjusted unless

authorized by Sonics

Service Department.

Do not operate press

without covers in place.

Go To Top Of Document

Advertising