I N S T R U C T I O N M A N U A L • M O D E L G X E P O W E R S U P P LY

38

SINKING OUTPUT TO PLC INPUT DIAGRAM

When the optical IC is placed into socket U43, the G series outputs are

configured as “Sinking.” The isolated transistor emitters must be connected

to the return line of the loop supply (all 4 emitters are connected together;

signal name Voltage Sink Return (output); pin 19 on I/O Connector J3; cable

wire – blu/red).

When the G series output is true or ON, current from the loop supply is

conducted through the PLC input card, the G series output transistor and

100 ohm limiting resistor to the loop supply return line.

See schematic drawing on page 43 for more detail.

PLC OUTPUT TO SINKING INPUT DIAGRAM

When the optical IC for input configuration is placed into socket U28, the G

series inputs (DI1, DI2, DI3, DI4) are configured to receive a “Sinking” input,

a pull down transistor or relay contact to the loop return. The anodes of the

input LEDs must be connected to a user supplied loop supply; +30 VDC max

(all 4 LED anodes are connected together; signal name +VDC Sink-Input; pin

12 on I/O Connector J3; cable wire – black/white).

When the PLC output is true or ON, current from the loop supply is

conducted through the G series opto LED and 2.4 kohm limiting resistor to

the PLC output card which returns to the loop supply. If the PLC output is

ON (conducting), the current is returned to the loop return line and the input

is true or ON. If the PLC output is OFF the G series input is false or OFF.

See schematic drawing on page 44 for more detail.

PLC OUTPUT TO SOURCING INPUT DIAGRAM

When the optical IC for input configuration is placed into socket U44, the G

series inputs are configured to receive a “Sourcing” input, a high side

transistor or relay contact to the positive loop supply. The cathode side of the

input LEDs must be connected to the return line of the loop supply (all 4

cathodes are connected together; signal name Voltage Source Return –

input; pin 13 on I/O Connector J3; cable wire – red/white).

When the PLC output is true or ON, current from the loop supply is

conducted through the PLC output element to the G series input opto LED

and limiting 2.4 kohm resistor to the return of the loop supply. If the PLC

output is ON (conducting) the G series input is true or ON. If the PLC output

is OFF the G series input is false or OFF.

See schematic drawing on page 45 for more detail.