Sure Heat CVS303 Natural Gas Conversion Kit User Manual

Lp/natural gas safety pilot kit model: cvs-303

Advertising
background image

LP/NATURAL GAS SAFETY PILOT KIT

MODEL: CVS-303

Supplemental Installation Instructions for use on

Emberglow Natural Gas Vented Log Sets

FOR INFRARED BURNER SYSTEMS ONLY

NOTE: This kit is for Natural Gas and L.P. Gas applications. For L.P. or Propane Gas installation see separate

instructions packaged with necessary hardware. (Do not use the Natural Gas orifice supplied with this kit on

L.P. or Propane Gas Installations as improper combustion will occur.

IMPORTANT

Read and follow all instructions carefully as these supplemental Pilot Assembly instructions are to be used in

conjunction with the General Installation Instructions supplied with all Emberglow Natural Gas log sets.

PARTS LIST & ILLUSTRATION

Part No.

Description

Part No.

Description

Part No.

Description

1

Control Knob

12

Pilot Orifice - Natural Gas

20a

3/8” Natural Gas Orifice -

18” Small Center Hole

3

Gas Control Valve

14

Pilot Supply Line Nut

5

Thermocouple Lead

15

Heat Shield

6

Pilot Gas Supply Line

16

Lock Nut

20b

3/8” Natural Gas Orifice -

24” & 30” Large Center Hole

7

Pilot Burner

17

90 Degree Street Elbow

8

Pilot Bracket

18

3” Pipe Nipple

9

Sheet Metal Screw (1)

19

3/8” Female Elbow (2)

21

3/8 Flare to 3/8 NPT

National Code requirements mandate the use of a Pilot Safety Valve on all L.P. or Propane gas

applications. These regulations must be followed on all installations of this type.

Advertising