Sure Heat CVS303 LP Conversion User Manual

Liquid propane conversion kit

Advertising
background image

Liquid Propane Conversion Kit

Supplemental Installation Instructions

for LP/NG Pilot Kit (CVS303)

For use with Dual and Infrared Burner Systems

(Used on Vented Gas log sets only)

NOTE: SAFETY PILOT SYSTEM MODEL CVS-303 MUST BE USED

WHEN INSTALLING THIS CONVERSION KIT.

IMPORTANT

Please read and follow all instructions carefully. These instructions are to be used in conjunction with

the General Installation Instructions supplied with all Vented Natural Gas sets. These instructions are

also used in conjunction with the Safety Pilot Kit instructions (Model CVS-303) included with this kit.

National Code requirements mandate the use of a Safety Pilot Valve on all Liquid Propane

Gas log installations. These regulations must be followed on all installations of this type.

CONVERSION KIT PARTS LIST:

PART

NO.

DESCRIPTION

A

18” L.P. AIr Shutter Orifice - small hole size

B

24” & 30” L.P. Air Shutter Orifice - large hole size

C

3/8 NPT x 1/8” Flare

D

Pilot Burner Orifice

E

18” L.P. Infrared Orifice (#56 drill size) - smaller size

F

24” L.P. Infrared Orifice (#53 drill size)

NOTE: Be sure to use pipe compound on all male threads to seal joints.

Sure Heat Manufacturing • 1861 West Oak Parkway • Marietta, GA • 30062• 1-800-229-5647

A

B

C

D

E

F

Pilot Orifice Location

Advertising