Decompression dives – SUUNTO Zoop User Manual

Page 38

Advertising
background image

36

WARNING DO NOT EXCEED THE MAXIMUM ASCENT RATE! Rapid ascents

increase the risk of injury. You should always make the Mandatory

and Recommended Safety Stops after you have exceeded the

maximum recommended ascent rate. If this Mandatory Safety Stop

is not completed the decompression model will penalize your next

dive(s).

3.3.5. Decompression dives

When your NO DEC TIME becomes zero, your dive becomes a decompression stop

dive, i.e. you must perform one or several decompression stops on your way to the

surface. The NO DEC TIME on your display will be replaced by an ASC TIME nota-

tion and the maximum depth will be replaced by a CEILING notation and an upward

pointing arrow (Fig. 3.15.).

If you exceed the no-decompression limits on a dive, the dive computer will provide

decompression information required for ascent. After this, the instrument will continue

to provide subsequent interval and repetitive dive information.

Rather than requiring you to make stops at fixed depths, the dive computer lets you

to decompress within a range of depths (Continuous Decompression).

The ascent time (ASC TIME) is the minimum amount of time needed to reach the

surface in a decompression dive. It includes:

• the time needed to ascend to the ceiling at an ascent rate of 10 m/min [33 ft/min]

plus

Advertising