PRELIMINARY

CY14B101Q1
CY14B101Q2
CY14B101Q3

Document #: 001-50091 Rev. *A

Page 15 of 22

AC Switching Characteristics

Cypress

Parameter

Alt.

Parameter

Description

40MHz

Unit

Min

Max

f

SCK

f

SCK

Clock Frequency, SCK

40

MHz

t

CL

t

WL

Clock Pulse Width Low

11

ns

t

CH

t

WH

Clock Pulse Width High

11

ns

t

CS

t

CE

CS High Time

20

ns

t

CSS

t

CES

CS Setup Time

10

ns

t

CSH

t

CEH

CS Hold Time

10

ns

t

SD

t

SU

Data In Setup Time

5

ns

t

HD

t

H

Data In Hold Time

5

ns

t

HH

t

HD

HOLD Hold Time

5

ns

t

SH

t

CD

HOLD Setup Time

5

ns

t

CO

t

V

Output Valid

9

ns

t

HHZ

t

HZ

HOLD to Output High Z

15

ns

t

HLZ

t

LZ

HOLD to Output Low Z

15

ns

t

OH

t

HO

Output Hold Time

0

ns

t

HZCS

t

DIS

Output Disable Time

25

ns

Figure 21. Synchronous Data Timing (Mode 0)

Figure 22. HOLD Timing

HI-Z

VALID IN

HI-Z

CS

SCK

SI

SO

tCL

tCH

tCSS

tSD

tHD

tCO

tOH

tCS

tCSH

tHZCS

CS

SCK

HOLD

SO

tSH

tHHZ

tHLZ

tHH

tSH

tHH

~ ~

~ ~