Installation Note

Description

1. The TII 90-3 Sealed Bridging Module provides

sealed IDC terminations for connecting six
additional extensions to an existing phone line.
The module can be installed directly into all TII
Network Interface Devices and can be
adapted to fit into a CAC 7600 footprint using
an optional adapter.

Installation

Installing The 90-3 Into A TII
3600/3700/9600/5300 NID

1. Locate the Network Interface Device

2. Unlock the subscriber access cover screw

using a standard screwdriver (Figure 2).

3. Identify the appropriate line position to add the

bridging module.

4. Snap the bridging module to the base as

shown in Figure 3. For installation into a TII
3600/3700/9600/5300 NID, the adapter is not
required.

5. Terminate wire leads (Tip/Ring) from the

bridging module to terminals on the existing
Customer Bridge Module.

6. Do not strip wire insulation from wires to be

terminated to CBM.

7. Lift all CBM rockers to the open position as

shown (see Figure 1).

8. Hold the customer telephone wires between

thumb and index finger (approx. 1/8”
separation between wires).

Figure 2

Figure 3

Adapter
(CAC 7600 Only)

Green (Tip)

Red (Ring)

Figure 1

Telco Shield Screw

Telco Access Screw

Subscriber Access Screw

Locking
Bar Tab

TII NID Base

Retaining Tab