Connecting to both ac and dc power in the switch – Cisco 3750 User Manual

Page 53

Advertising
background image

3-13

Catalyst 3750 Metro Switch Hardware Installation Guide

OL-9160-02

Chapter 3 Connecting the Power Supply

Connecting to Both AC and DC Power in the Switch

Step 4

Use a Phillips screwdriver to remove the screw at the lower-left that secures the power supply unit to
the switch chassis.

Step 5

Remove the power supply unit from the power slot by pulling on the power-on restrictor (see

Figure 3-18

).

Connecting to Both AC and DC Power in the Switch

You can install an AC power supply or a DC power supply in either slot. You can also install an AC
power supply in one slot and a DC power supply in the other slot.

Caution

If a DC power supply is present in your configuration, you must install a grounding lug on the switch.

See the section that applies to your configuration:

To install an AC power supply in one of the slots, see the

“Connecting to AC Power” section on

page 3-1

.

To install a DC power supply in either slot, see the

“Connecting to DC Power” section on page 3-4

.

To remove an AC power supply, see the

“Removing the AC Power Supply” section on page 3-3

.

To remove a DC power supply, see the

“Removing the DC Power Supply” section on page 3-12

.

Warning

This unit might have more than one power supply connection. All connections must be removed to
de-energize the unit.
Statement 1028

Advertising