Upflow furnace components, Downflow furnace components, Model 58vua upflow furnace – Carrier 58VCA User Manual

Page 4: Model 58vca downflow furnace

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

UPFLOW FURNACE COMPONENTS

m

s

m

m

m

m

m

11

Gas valve. Safe, efficient. Features 2 separate gas
shut-off valves.
Burner assembly (inside). Operates with energy­
saving pilot, inshot burners, and spark igniter

for safe, dependable heating.
Primary serpentine heat exchanger (inside).

Stretches fuel dollars with the S-shaped heat-

flow design. Solid construction of corrosion-
resistant aluminized steel means reliability.
Secondary condensing heat exchanger (inside).
Wrings out more heat through condensation.
Constructed with polypropylene-laminated steel
to ensure durability.
Inducer motor. Pulls hot flue gases through the

heat exchangers, maintaining negative pressure
for added safety.
Vent outlet. Uses PVC pipe to carry vent gases

from the home.
Condensate drain trap. Collects moisture

condensed from burned gases for disposal into
home drain system.
Heavy-duty blower. Circulates air upwards,

scrubbing the heat exchangers to speed
condensation and transfer extra heat into the
home.
Air filter and retainer spring.

Light emitting diode (LED) view port. Fault
code lights are inside.
Low-voltage circuit breaker.

DOWNFLOW FURNACE COMPONENTS

m

B

B
B

10

Gas valve. Safe, efficient. Features 2 separate gas
shut-off valves.
Burner assembly (inside). Operates with energy­
saving pilot, inshot burners, and spark igniter

for safe, dependable heating.
Primary serpentine heat exchanger (inside).

Stretches fuel dollars with the S-shaped heat-
flow design. Solid construction of corrosion-
resistant aluminized steel means reliability.
Secondary condensing heat exchanger (inside).

Wrings out more heat through condensation.
Constructed with polypropylene-laminated steel
to ensure durability.

Inducer motor. Pulls hot flue gases through the
heat exchangers, maintaining negative pressure
for added safety.

Vent outlet. Uses PVC pipe to carry vent gases
from the home.
Condensate drain trap. Collects moisture

condensed from burned gases for disposal into
home drain system.
Heavy-duty blower. Circulates air downward,

scrubbing the heat exchangers to speed
condensation and transfer extra heat into the

home.
Light emitting diode (LED) view port. Fault

code lights are inside.
Low-voltage circuit breaker.

A91237

MODEL 58VUA
UPFLOW FURNACE

A92097

11 Manual-reset auxiliary limit switch.

MODEL 58VCA
DOWNFLOW FURNACE

Note; See Fig. 28 for filter location.

Advertising