58SSB

...

..„„0

.0

Accessory Variable Speed Blower Kit

Installation Instructions

GENERAL

These instructions cover installation of an ECM blower

accessory on 2- and 3-ton cooling 58SSB 060 and 080
furnaces. ECM blower accessory Part No. 58SSB900131

is used on 2-ton cooling 58SSB060 furnace and Part No.
58SSB900141 is used on3-toncooling58SSB080furnace.

Each ECM blower kit comes completely assembled

with an ECM blower motor and controller, and interface
circuit board. See Table 1 for a list of parts in assembly
shown in Fig. 1.

ECM blower kit is used in conjunction with following

variable speed outdoor units:

38EV024320
38EV036320
38QV024320

38QV036320

This ECM blower is controlled by outdoor unit and

provides variable airflow across furnace coil in response
to variable demand on heat pump or air conditioner. For

emergency heat, interface circuit board allows furnace
control board to operate ECM blower at a fixed rate of

speed. This speed is normally adjusted to midpoint of
rating plate temperature rise range. Interface circuit
board also powers a Parker indoor thermostat. Part No.
HH05ZA001.

Installation of indoor coil expansion valve, and start­

up and adjustment instructions are covered in Installa­
tion, Start-Up and Service Instructions for the 38EV,QV
outdoor units. See detailed system operation and control
in the 38EV,QV system operation and troubleshooting

guide.

A WARNING

Turn off power at main disconnect switch before
starting installation to avoid possibility of electrical
shock.

TABLE OF CONTENTS

Page

INSTALLATION ..................................................................1-4

SEQUENCE OF OPERATION......................................... 5
TEMPERATURE RISE ADJUSTMENT.................... 6
CARE AND MAINTENANCE .......................................... 6,7

INSTALLATION

The following steps should be performed by a qualified

service person:

1. Turn off power at main disconnect.

2. Remove blower door.
3. Remove control box from bottom side of blower

shelf and position out of way.

4. Remove electrical leads from numbered side of

blower speed selector.

5. Remove screws securing blower assembly to blower

shelf and slide blower assembly out of furnace.

6.

Unpackage ECM blower assembly and set the

minimum and maximum torque settings on ECM
blower control via access in lower mounting bracket
as shown in Fig. 2.

Table 1 — ECM Blower Kit Parts List

ITEM

DESCRIPTION

QUANTITY

58SSB900131

PART NO.

58SSB900141

PART NO.

1

Housing-Blower

1

58SSB309891-701

58SSB309891-702

2

Band-Motor Mount

1

HC98ZZ480

HC98ZZ480

3

Arm-Motor Mount

3

HC98ZZ242

HC98ZZ248

4

Wheel-Blower

1

LA22RA101

LA22RA100

5

T ransformer

1

HT01AW232

HT01AW232

6

Motor (ECM)

1

HC42SE113

HC42SE113

7

ECM Motor Controller

1

HR46KH001

HR46KH001

8

Top Blower Control Bracket

1

58SSB308056-201

58SSB308056-201

9

Bottom Blower Control Bracket

1

58SSB308056-202

58SSB308056-202

10

Grommet-Isolator

3

09-0135

09-0135

11

Interface Board

1

HK42FA002

HK42FA002

12

Interface Box

1

58SSB309863-401

58SSB309863-401

13

Interface Box Cover

1

58SSB309864-301

58SSB309864-301

14

Cutoff, Blower

1

79725-2

79725-3

15

Electrical Noise Suppressor

1

HK99FA001

HK99FA001

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obiigations.