Initial start-up – Carrier 58BB User Manual

Page 8

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

IMPORTANT; Remove shippmg pad from

motor moiintkig angle before operating blower.

Initial Start-Up

When first lighting furnace pilot:

1. Open all warm air registers.

2. Set room thermostat to lowest setting.
3. If humidifier is installed with system, open

water supply valve.

4. If line voltage switch is provided in furnace

circuit, turn it to “Off” position.

5. Turn gas cock dial (see Fig. 7 and Fig. 8) to

“Off” position.

6. Wait approximately 5 minutes to allow gas

wliich may have accumulated in burner com­
partment to escape.

7. Turn gas cock dial to “Pilot” position.

8. On Unitrol 7000 valves, depress and hold gas

cock dial while lighting pilot burner. If valve is
equipped for 100% shutoff, allow pilot to burn

a p p r o x i m a t e l y

one-half

minute

before

releasing dial (Unitrol 7000 valve) or before
depressing automatic pilot reset button (Essex
TF 555 valve). If pilot does not remain lighted,
repeat operation allowing longer period before
releasing dial or depressing button. If neces­

s a r y ,

a d j u s t

pilot.

(See

Pilot

Burner

Adjustment.)

9. Turn gas cock dial to “On” position.

10. Set room thermostat at desired temperature

position.

IMPORTANT; For the Unitroi 7000 models
equipped with a pressure regulator, do not
adjust gas input between “Pilot” and “On”

positions on the gas cock dial.

START-UP AND SERVICE

Pilot Burner Adjustment

1

.

2

.

3.

Remove pilot adjustment cap. (See Fig. 7.)

Adjust pilot key to provide properly sized

flame. (Ignition flame should extend outward

and upward approximately 1.5 in. from the
stem of the pilot.) Turn screw clockwise for
high flame or counterclockwise for low flame.

Replace pilot adjustment cap.

Combustion Air Adjustment

Primary air shutters are provided on all furnaces

to enable adjustment of the primary air supply to
get proper flame characteristics. Adjust the air
shutters as follows;

1.

After furnace has been operating for 15

minutes, loosen air shutter screw on each
burner face.

2

.

3.

Close air shutter until yellow tips appear in
flame. Then, open air shutter until yellow tips
disappear and flame has soft blue cone.
Secure air shutters in position by tightening

each air shutter screw.

Blower Speed Adjustment

Adjust on installation for nameplate tempera­

ture rise. (See Table 1.)

1. For direct drive speed change (58BB furnaces),

perform the following;
a. Rotate speed-change plug or move line lead

from fan switch to desired speed terminal.

When plug is rotated, desired speed marking

should face away from motor shaft.
Speeds on plug are marked. High (•),

Medium-High (••), Medium-Low (•••), and

Low (••••)

b. For speed selection on direct drive model

with terminal connections, change terminal
at motor. (See Fig. 5 and Fig. 6.)

C

GAS COCK DIAL

PILOT
CONNECTION

OUTLET
(NOT VISIBLE)

AUTOMATIC
PILOT RESET
BUTTON*

PRESSURE TAP

(NOT VISIBLE)

PILOT ADJUSTMENT
CAP

VENT

REGULATOR

ADJUSTMENT

SCREW CAP

GAS COCK DIAL

PILOT
CONNECTION

PILOT
ADJUSTMENT
CAP

thermocouple

CONNECTION

VENT

(NOT VISIBLE)

REGULATOR
ADJUSTMENT

SCREW CAP

-

outlet

(NOT VISIBLE)

PRESSURE

TAP

(NOT VISIBLE)

ESSEX TF 555

(Used on 58BB Furnaces)

UNITROL 7000

(Used on 58BD Furnaces)

•"Available only on valves equipped for 100% shutoff.

Fig. 7 — Combination Gas Valves

Advertising
This manual is related to the following products: