A warning, To shut unit off, Maintaining your unit – Carrier 48TJE004-014 User Manual

Page 2

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

Step 8 — Turn on the electrical supply to unit.

Step 9 — Open the manual gas valve.

Step 10 — Set room thermostat selector slightly above
room temperature to start unit. The induced-draft combus­
tion air fan will start. Main gas valve will open and main
burners should ignite within 5 seconds. If the burners do
not light, there is a 22-second delay before another 5-second
try. If the burner still does not light, the time delay is re­
peated. If the burner does not light within 15 minutes, there
is a lockout. If burners still do not light, call for service.

Step 11 — Set the temperature selector on room ther­
mostat to desired setting.

A

WARNING

If the main burners fail to light, or the blower fails to
come on, shut down gas heating section and call your
dealer for service. Failure to follow these requirements
could result in serious personal injury.

TO SHUT UNIT OFF

A

WARNING

2

.

Do not turn off the electrical power to unit without
first turning off the gas supply.
Never attempt to manually light the main burners
on unit with a match, lighter, or any other flame. If
the electric sparking device fails to light the main
burners, refer to the following shutdown proce­
dures, then call your dealer as soon as possible.

Failure to follow these procedures can result in

serious fire or personal injury.

Refer to Fig. 3 while proceeding with the following steps.

Step 1 — Set room thermostat to lowest temperature set­
ting and set SYSTEM switch to OFF position.

Step 2 — Close the external manual gas valve.

Step 3 — Turn off the electrical power supply to unit.

Step 4 — Remove the burner access panel.

Step 5 — Turn the control dial on the gas valve
clockwise to the OFF position.

Step 6 — Replace the burner access panel.

Step 7 — If unit is being shut down because of a mal­
function, call your dealer as soon as possible.

If unit is being shut down because the heating season has

ended, restore electrical power to the unit to ensure opera­
tion of the cooling system during the cooling season.

Should overheating occur, or the gas supply fail to shut

off, shut off the manual gas valve to the unit before shut­
ting off the electrical supply.

Do not use this unit if any part has been under water.

Immediately call a qualified service technician to inspect
the unit and to replace any part of the control system and

any gas control which has been under water.

MAINTAINING YOUR UNIT

All maintenance should be handled by skilled, experi­

enced personnel. Your dealer can help you establish a stand­
ard procedure.

For your safety, keep the area around the unit clear and

free of combustible materials, gasoline, and other flamma­
ble liquids and vapors.

To ensure proper functioning of the unit, flow of com­

bustion and ventilating air must not be prevented from reach­
ing the unit. Clearance of at least 3 ft on 004-007 units and
4 ft on 008-014 units on the flue and condenser sides and
6 in. on all other sides is required. A clearance of 5 ft is
required above the condenser discharge

ROUTINE MAINTENANCE AND CARE

FOR THE EQUIPMENT OWNER

Consider the following information before maintaining

or servicing equipment:

A

WARNING

1. TURN OFF GAS SUPPLY AND THEN ELECTRI­

CAL POWER TO YOUR UNIT BEFORE SER­
VICING OR PERFORMING MAINTENANCE.

2. Do not turn off electrical power to this unit without

first turning off the gas supply.

3. When removing access panels or performing main­

tenance functions inside your unit, be aware of sharp
sheet metal parts and screws. Although special care
has been taken to reduce sharp edges inside the unit,
be extremely careful when handling parts or reach­
ing into the unit.

©

Advertising
This manual is related to the following products: