Origina* *]® Remote Fan & Light Control
Model 27187

Ratings:

120 VAC, 60 Hz, 2.0 Amp Fan Receiver Weight 16 oz.

300 Watt incandescent light

Read and Save these Instructions

Caution: Risk of Electrical Shock!

Ail wiring must be performed in accordance with national and

local electrical codes. If you are unfamiliar with the wiring
codes, you should use a qualified electrician.

To avoid overheating and possible damage to other equip­
ment, do not install to control a receptacle, fluorescent light

fixture, motor operated appliance, or transformer-supplied
appliance. Use only to control one paddle-blade ceiling fan
and incandescent light fixture.

Notes:

1. This device complies with Part 15 of the FCC Rules. Operation is
subject to the following two conditions: (1) this device may not cause
harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.

2. This equipment has been tested and found to comply with the lim­
its for a Class B digital device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment gen­
erates, uses and can radiate radio frequency energy and, if not
installed and used In accordance with the instructions, may cause
harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation.

If this equipment does cause harmful interference to radio or televi­

sion reception, vy.hich can be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference by
one or more of the following measures:

• Reorient or relocate the receiving antenna.

• Increase the separation between the equipment and receiver.

• Connect the equipment into an outlet on a circuit different from

that to which the receiver is connected.

• Consult the dealer or an experienced radio/TV technician for help.

3. For use only with electrically reversible ceiling fans rated at 2.0
amps or less, and fan incandescent light kits rated at 300 watts or less.

4. Not for use with shaded-pole or non-reversible motors.

5. Medium and Low fan speeds are determined by the Original®
control and thus may vary from the factory settings due to normal
motor variations.

Before^lnstallingi the Original® Control:

ii. Confirm thafyour Hunter Original® ceiling fan is electrically
reversible. Look for a reversing switch on the switch housing below
the motor. Refer to Figure 1.

2. Use the pull-chain switch to set the fan speed to the HIGH position
before installation. Do not use the pull-chain to change the fan speed
after installation, as damage to your ceiling fan or control may result.

The speed of thè fan should only be changed by the Original® control.

3. Set the ceiling fan light kit to the ON position before installation.
The light level should only be changed by the Original® control.

Receiver Installation:

1. Disconnect power to the ceiling fan and light kit at the main elec­

tric panel. Remove fuse or move circuit breaker to the OFF position.

2. IMPORTANT! Before installing this control, change the factory

Select your own unique code, being sure settings match in the
transmitter and receiver.

default dip switch settings to your own unique code. Refer to Figure 2.
Be sure the dip switch positions of the transmitter and receiver match,
or the ceiling fan will not function.

Select different combinations of dip switches to prevent mis-operation
due to other remote control fans, garage door openers, etc.

3. This Original® remote control mounts between the ceiling and fan
hanger bracket. Therefore, if the fan is already installed, it will need
to be taken down.

4. Wire the power leads coming from the ceiling outlet box. Connect
the main wires from the

top

of the control - white to white, and

black to black. See Figure 3. Push the wires up into the outlet box
and arrange the wire connectors to point upward. Separate the wires
so that the black wires are on one side of the box and the white
wires are on the other.

5. Bring the control up to the ceiling. Feed the bare copper ground

wire down through the center hole of the control. Use the lag screws

(included) to hold the control and and the fan mounting bracket in
place. See Figure 4.

6

.

Mount the fan to the fan hanger. Connect the white wire from the

control to the fan white wire and the black wire to the black.
Connect the bare copper wire to the green ground wire from the fan.
Connect the red wire from the control to the fan through-wire that
goes directly to the light kit. See Figure 5. Push the connections up

through the center hole into the ceiling outlet box.

7. Complete the installation of the fan by following the instructions

supplied with the fan.

8. Restore power at main electrical panel.