Advanced functions – Sekonic L-358 User Manual

Page 25

Advertising
background image

-21-

6. Advanced Functions

1.

Memory function
This meter can store up to nine measured values in memory. This feature can be used in the follow-
ing modes: ambient light (shutter speed priority, aperture priority and EV), flash (with, without cord
and wireless flash radio triggering).

1.

Press the Measuring button !5 and take a measure-
ment.

2.

Press the Memory button u and store the measured
value in memory.
The number of values in memory is displayed on
the LCD. The memorized value is displayed on the
analog scale. By repeating this operation, up to nine
values can be stored in memory.

3.

Memory can be cleared by holding down MODE set
button !0 and ISO 2 button y or changing mea-
surement mode.

4.

Memory Recall
When the Jog wheel !0 is rotated while both Memory
button t and the Mode set button !0 are held down
together, the measured value stored in the memory
is displayed along with the memory number. When
any previous stored value is recalled with the ex-
ception of the last stored value, the “M” and number
will blink.

NOTE:

• The memory function cannot be used in "flash cumulative mode."
• Measured values for ten times and over will be displayed but cannot be stored in memory.

1/10
f stop

Measured f stop
value

Memoreized
f stop values

Set shuttter
speed

Number of
memorized value

MEMORY

Advertising