If the key unit or control unit is defective, When testing is completed, 12] procedure k : key unit test – Sharp Carousel R-305KS User Manual

Page 18: 12] procedure k : key unit test -5, R305ks

Advertising
background image

R305KS

8 – 5

b) At a certain digit, brightness is low.

c) Only one indicator does not light.

d) The corresponding segments of all digits do not light up; or they continue to light up.

e) Wrong figure appears.

f) A certain group of indicators do not light up.

g) The figure of all digits flicker.

3) Other possible problems caused by defective control unit.

a) Buzzer does not sound or continues to sound.

b) Clock does not operate properly.

c) Cooking is not possible.

3. If the Key unit or control unit is defective.

1) Disconnect the power supply cord, and then remove outer case.

2) Open the door and block it open.

3) Discharge high voltage capacitor.

4) Replace the control unit assembly.

5) Reconnect all leads removed from components during testing.

6) Re-install the outer case (cabinet).

7) Reconnect the power supply cord after the outer case is installed.

8) Run the oven and check all functions.

4. When testing is completed,

1) Disconnect the power supply cord, and then remove outer case.

2) Open the door and block it open.

3) Discharge high voltage capacitor.

4) Reconnect all leads removed from components during testing.

5) Re-install the outer case (cabinet).

6) Reconnect the power supply cord after the outer case is installed.

7) Run the oven and check all functions.

[12] Procedure K : KEY UNIT TEST

1. Disconnect the power supply cord, and then remove outer case.

2. Open the door and block it open.

3. Discharge high voltage capacitor.

4. Using an ohmmeter and referring to the key unit matrix indicated on the control unit circuit, check the circuit between the pins of the key unit that

correspond to the STOP/CLEAR pad. When the pad is pressed, the ohmmeter should indicate short circuit. When the pad is released, the ohmme-
ter should indicate open circuit. If incorrect readings are obtained, the key unit is faulty and must be replaced. About the other pads, the above
method may be used.

5. Reconnect all leads removed from components during testing.

6. Reinstall the outer case (cabinet).

7. Reconnect the power supply cord after the outer case is installed.

8. Run the oven and check all functions.

Advertising